Bently Nevada 128718-01 is a Euro-style external termination block for 3500/25 Keyphasor I/O modules. It provides the field-wiring interface for phase-reference transducers and links the external terminations to the matching rear I/O module in a 3500 machinery-protection rack.
Model Identification
Retain the complete 128718-01 part number. This version uses Euro-style connectors and must not be confused with 128726-01 terminal-strip hardware or an internal-termination I/O module.
Compatibility Check
Confirm a 3500/25 Keyphasor module with external-termination I/O, the matching interconnect cable, channel count, transducer type, cabinet mounting and shield-ground arrangement. External blocks cannot be substituted for internal-termination configurations.
Typical Applications
Keyphasor field-signal termination
Speed and phase-reference wiring
3500 rack external termination
Turbine and compressor monitoring
Installation and Replacement Notes
De-energize the monitoring circuit, label every field conductor and shield, record terminal positions, mount the block securely, connect only the approved cable and verify sensor bias and Keyphasor pulse quality before return to service.
Technical and System Review
Confirm Euro-style terminals, 3500/25 external-termination architecture, compatible I/O module 126648-01 or 126648-02, transducer power requirements, shield grounding and cabinet environmental conditions.
Inquiry Evidence
Provide the 128718-01 label, quantity, installed 3500/25 and I/O module numbers, termination style, cable part number, transducer type and clear photographs of the terminal block and wiring.
Q: What is the exact model to order for 128718-01?
A: Order the complete 128718-01 catalog number and confirm the series and label on the installed module.
Q: What function does 128718-01 perform?
A: It terminates external Keyphasor transducer wiring and routes phase-reference signals to a compatible 3500/25 rear I/O module.
Q: Is 128718-01 suitable for every installation?
A: No. Confirm a 3500/25 Keyphasor module with external-termination I/O, the matching interconnect cable, channel count, transducer type, cabinet mounting and shield-ground arrangement. External blocks cannot be substituted for internal-termination configurations.
Q: What information should accompany a 128718-01 inquiry?
A: Provide the 128718-01 label, quantity, installed 3500/25 and I/O module numbers, termination style, cable part number, transducer type and clear photographs of the terminal block and wiring.
Q: What should be checked before installing 128718-01?
A: De-energize the monitoring circuit, label every field conductor and shield, record terminal positions, mount the block securely, connect only the approved cable and verify sensor bias and Keyphasor pulse quality before return to service.
Q: How are stock and physical data for 128718-01 handled?
A: The purchase summary lists 1 unit, 0.12kg and 9x7.6x6cm; final warehouse confirmation is required before order placement.